UPS Rack 10-20kVA

IST9-ups-online-rack

Power Range: 10-20 kVA

| IST9

Uninterruptible power supplies rack 19″ IST9 (10-20kVA) are AEC’s range of three-phase rack online UPS, in starting from 10kVA up to 20kVA. The UPS IST9 series adopts the most innovative technologies with 3 IGBT levels, guaranteeing an efficiency of up to 97% and a unitary output power factor.

IST9 can be configured in input \ output mode 1 | 1 or 3 | 1 or 3 | 3 directly from the display. Compact 19″ rack UPS, only 3U in rack cabinet height. The system includes a distribution module and a manual bypass disconnect for ease of maintenance.

1:1

3:1

3:3

three UPS levels

kW = kVA

97% Efficiency

More information

Download documentation

UPS 10-20 kVA for racks, data centers and IT

  • 19 “rack UPS with 3-level IGBT technology;
  • Maximum flexibility, advanced technology and space-saver;
  • Flexible configuration 1: 1, 3: 1, 3: 3 settable from the display;
  • UPS for rack cabinets with 97% efficiency;
  • Max. 10A Charging current and high AC / AC efficiency up to 97%;
  • Output power factor up to 1 and THDi <3%, with less energy pollution;
  • Parallelable rack UPS up to 4 units, supports up to 80kVA of single-phase or three-phase load;
  • Intelligent RS485 + EPO and ECO function configurable directly on site;
  • Easy to transport and to install;
  • UPS with tower and rack compatible design;
  • Number of batteries (24-40) and charging current adjustable.

3 year warranty.
Ideal for rack cabinets, data centers, servers and healthcare equipment.

Have you found the right product?

Buy it now from our shop! Find out prices, availability and configurations and order in just a few clicks.

Go to the shop

Accessories

Then by purchasing an IST9 UPS (10-20 kVA) the External Bypass is included in the price, which allows maintenance or repair / replacement of the UPS without interrupting the powered user.
It is also possible to purchase different accessories separately to implement the functionality of the UPS:
– Temperature sensor = monitors the batteries by compensating the charging current based on the ambient temperature thanks to a probe that communicates with the logic of the continuity system.
– SNMP card = allows AEC UPS to be remotely monitored, assisted, tested and operated anywhere in the world.
– Dry Contact card = provides a series of potential-free normally open or normally closed contacts to signal various UPS functions.

Dry Contact Card UPS Dry Contact Card

Learn more

SNMP Network Card SNMP Card for UPS

Learn more

External-Bypass

External maintenance bypass for UPS

Learn more

Download documentation

Technical specifications

Download

User manual

Download

Catalog

Download