Skip to content

UPS Modular 208V 15-90kVA

Power Range: 15-90 kVA

| RADIANT

RADIANT UPS is AEC’s modular three-phase, double-conversion online UPS series, available in power ratings from 15 kVA to 90 kVA.

The UPS is designed for 208 V, three-phase, 4-wire (3Ph + N + G) systems.

The system is built on 15 kW hot-swappable power modules installed in a 90 kVA frame with 6 module slots, supporting a maximum configuration of 90kW or 75 kW + 1 redundancy (5 × 15 kW active modules + 1 redundant module).

This architecture allows incremental capacity expansion and N+X redundancy, enabling module replacement without load interruption.

RADIANT operates with online double-conversion topology, delivering efficiency up to 94% and a unity (1.0) output power factor.

The system is equipped with a 7-inch touchscreen display for monitoring, configuration, and diagnostics.

3:3

Modular

Three UPS levels

kW = kVA

94% Efficiency

TIER 1 UPS Highest efficiency

High-rate VRLA Batteries

Warranty

Assistance

More information

Download documentation

Technical specifications

  • UPS Model: RAD60-XX10

Input

  • Voltage (VAC): 200/208/220VAC(L-L)
  • Frequency (HZ): 40~70Hz
  • Input range (VAC): 166-261Vac(L-L)@full load, 125-166Vac(L-L) power derate from 100% to 75%
  • Power factory: ≥0.99
  • THDI: ≤3%
  • Phase: 3W+N+G

Output

  • Power Module (kW): 10kVA
  • Frame capacity (kW): 60kVA (Max 6 Modules x 10kVA)
  • Power factor: 1
  • Voltage (VAC): 200/208/220VAC(L-L)
  • Frequency (HZ): 50/60±0.1
  • THD: ≤1%THD, linear load; ≤5%THD, non-linear load
  • Waveform: Pure sinewave
  • AC/AC Efficency: 96,00%
  • Overload: 110% 1 hour, 125%10 mins, 150% 1 min, >150% 200ms

Battery

  • Voltage (VDC): ±120Vdc (20 batteries) or ±132Vdc (22 batteries) settable by display
  • Standard battery set: ±120Vdc
  • Max. current Charger (A): 20% * UPS maximum capacity

Other specifications

  • Recharging time: < 6 Hours
  • Communications: Standard: RS232, E.P.O Contact and USB Port Optional: SNMP, Modbus, Dry contact
  • Noise (DB): <50dB
  • Temperature (°F – °C): 0°C – 40°C 32°F – 104°F
  • Umidity: <95%
  • Dimensions (W*D*H) in: 19*27.5*33 in (19U) wheels not included
  • Dimensions (W*D*H) cm: 48.2*70*83.8 cm (19U) wheels not included
  • Frame Weight (Lb – Kg): 207 Lb – 94 Kg
  • Power Module (Lb-Kg): 37.5 Lb – 17 Kg

Certifications

  • Standards: CE (IEC EN 62040-1; EMC IEC EN 62040-2; IEC EN 62040-3); UL1778

Advantages

Improved Voltage Control

A 3-level IGBT inverter introduces an intermediate voltage state (OV), yielding three discrete levels: +Vdc, OV, and Vdc.

Cleaner waveform

The staircase-shaped output more closely resembles a sine wave, reducing THD and interference.

Lower Harmonic Distortion (THD)

3 level IGBT reduces THD compared to the 2-level's rough waveform, improving power quality and reducing harmonic pollution.

Lower switching stress

Smaller voltage transitions mean each IGBT experiences less stress and switching loss, allowing for the use of lower-voltage, faster devices.

Higher efficiency

With reduced losses, heat dissipation and improved waveform quality, efficiency jumps above 96%, especially in new demanding critical power applications.

UPS Modular technology N+X

Modular UPS technology revolutionizes power protection by offering scalability, flexibility, and serviceability in a single solution. Unlike traditional monolithic systems, a modular UPS is composed of independent power modules that can be added, removed, or replaced without shutting down the system.

This architecture enables N+X redundancy, where “N” is the number of modules required to support the full load, and “X” represents additional modules for backup. For example, a 50 kW load can be protected by six 10 kW modules (N=5, X=1), ensuring continued operation even if one module fails.

Touch screen Smart Display

  • Clear Display: A 7-inch color touchscreen provides an easy and intuitive way to control the UPS.
  • Secure Access: Three access levels (User, Technician, Manufacturer protect system settings.
  • Full Configuration: Adjust input, output, battery, communication, language, and operating modes directly from the screen.
  • Live Monitoring: View real-time data like voltage, load, frequency, and battery status by cell at a glance.
  • Event History: The UPS logs up to 10,000 events, downloadable via the built-in USB port.
  • Generator Ready: Advanced settings ensure stable operation and communications with diesel generators.
  • Custom Alarms: Set and manage dry contact alarms right from the touchscreen.
  • Self-Cleaning: Automatic fan cycles help remove dust and keep internal parts clean.
  • Waveform Display: The system periodically records inverter, rectifier, and control waveforms for diagnostics.

MODEL : RAD90-XX15

Found the right product?

Buy it now from our shop! Discover prices, availability, and configurations, and order in just a few clicks.

Go to the shop

Download documentation

RADIANT 10-60k 208V Modular Catalog

Download

Fill out the form to request more information

JavaScript is needed to send the form. Alternatively, write to sales@aecups.com.