Power Range: 1-3 kVA

UPS Online tower 120V

| FERRUS

FERRUS UPS is AEC’s single-phase double-conversion online UPS series, available in tower format with power ratings from 1 kVA to 3 kVA.

The series is based on IGBT three-level inverter technology, delivering efficiency up to 94.5% and a unity (1.0) output power factor, allowing full active power delivery.

FERRUS UPS systems are available with internal batteries or can be configured with external battery cabinets to support extended backup runtime.

The UPS operates with single-phase 110/120 V input and output and features automatic frequency sensing at 50/60 Hz, ensuring compatibility with different power sources

Three UPS levels

kW = kVA

94.5% Efficiency

TIER 1 UPS Highest efficiency

High-rate VRLA Batteries

8A Charger for fast recharge

Warranty

Assistance

 

 

 

INPUT
VOLTAGE (VAC) 55-150Vac
FREQUENCY (HZ) 40~70Hz Auto-sensing
INPUT RANGE (VAC) 100% load@>90Vac 70% load@>70VAC 40% load@>50VAC
POWER FACTORY ≥0.99
THDI ≤3%
SOCKET – PLUG C14 5ft input cable to L-20 5ft input cable to L5-30
OUTPUT
POWER CAPACITY (W) 1000 2000 3000
POWER FACTOR 1
VOLTAGE (VAC) 100/110/115/120Vac
FREQUENCY (HZ) 50/60±0.1
THD ≤1%THD, linear load; ≤5%THD, non-linear load
WAVEFORM Pure sinewave
AC/AC EFFICENCY 94.5%
OVERLOAD 102%~110%: 10mins, 111%~130%:1mins,131%~150%: 30 seconds
SOCKET – PLUG 6 x NEMA 5-15R 8 x NEMA 5-20R 6xNEMA5-20R + 1xNEMA5-30R
BATTERY
VOLTAGE (VDC) 24Vdc 48Vdc 72Vdc
STANDARD INTERNAL BATTERY 2x 12V/9Ah 4x 12V/9Ah 6x 12V/9Ah
MAX. CURRENT CHARGER (A) Max 8A settable 1-8
OTHER SPECIFICATIONS
RECHARGING TIME < 6 Hours
COMMUNICATIONS Standard: RS232, E.P.O Contact and USB Port Optional: SNMP, Modbus, Dry contact
NOISE (DB) <50dB
TEMPERATURE (°F – °C) 0°C – 40°C 32°F – 104°F
UMIDITY <95%
DIMENSIONS (W*D*H) IN 5.6*13.9*8.6 in 5.6*15.6*8.6 in
DIMENSIONS (W*D*H) CM 14.2*35.3*21.6 cm 14.2*39.6*21.6 cm
WEIGHT (LB – KG) 16.5 Lb – 7.5 Kg 36.3 Lb – 16.5 Kg 45.2 Lb – 20.5 Kg
CERTIFICATIONS
STANDARDS CE (IEC EN 62040-1; EMC IEC EN 62040-2; IEC EN 62040-3); UL1778

Catalog\Brochure Ferrus UPS 1-3kVA

Ferrus_AECUPS_120V_1-3k_Catalog
PDF - 1 MB

Advantages

Cleaner Waveform

The 3-level IGBT inverter delivers superior performance by switching between +Vdc, OV, and -Vdc, producing a cleaner, more sinusoidal output.

Low THD

Minimizes distortion and interference.

High Efficiency

Exceeds 94% with reduced switching losses.

Compact Design

Smaller filters lower cost and space.

Enhanced Reliability

Reduced stress extends component life.

Cleaner Waveform

The 3-level IGBT inverter delivers superior performance by switching between +Vdc, OV, and -Vdc, producing a cleaner, more sinusoidal output.

Low THD

Minimizes distortion and interference.

High Efficiency

Exceeds 94% with reduced switching losses.

Compact Design

Smaller filters lower cost and space.

Enhanced Reliability

Reduced stress extends component life.

UPS Online double conversion

An Online Double-Conversion UPS constantly converts incoming AC to DC and back to AC. This means your devices always receive clean, perfectly regulated power with zero transfer time—there’s never a moment of interruption, even during a blackout.

In contrast, a Line-Interactive UPS usually runs on mains power and switches to battery only when voltage swings too far, causing a brief interruption of about 2-10 ms.

 

Smart LCD Display

The integrated LCD display offers real-time visibility and complete control over all critical UPS parameters. Users can easily monitor input, bypass, and output voltages, load status, battery level, frequency, temperature, and communication settings-all from a single interface.

Key features include:

  • User-friendly navigation for quick access to system information and configuration.
  • Adjustable charger current (1-4/8A) directly from the display.
  • Customizable output voltage settings for site-specific needs.
  • Status indicators and event logs for fast diagnostics and performance tracking.
  • Designed for both technicians and end users, the display ensures intuitive control and rapid access to the UPS.

 

MODELS : FER1000-2X9 | FER2000-4X9 | FER3000-6X9

Input

Voltage (VAC)55-150Vac
Frequency (HZ)40~70Hz Auto-sensing
Input range (VAC)100% load@>90Vac 70% load@>70VAC 40% load@>50VAC
Power factory≥0.99
THDI≤3%
Socket - PlugC14 | 5ft input cable to C-20 | 5ft input cable to L5-30

Output

Power capacity (W)1000 | 2000 | 3000
Power factor1
Voltage (VAC)100/110/115/120Vac
Frequency (HZ)50/60÷0.1
THDTHD
WaveformPure sinewave
AC/AC Efficency94.5%
Overload102% ~ 110%: 10mins, 111% ~130%: 1mins, 131% ~ 150%: 30 seconds
Socket - Plug6 x NEMA 5-15R | 8 x NEMA 5-20R | 6xNEMA5-20R +

Battery

Voltage (VDC)24Vdc | 48Vdc | 72Vdc
Standard internal battery2x 12V/9Ah | 4x 12V/9Ah | 6x 12V/9Ah
Max. current Charger (A)Max 8A settable 1-8

Other specifications

Recharging time< 6 Hours
CommunicationsStandard: RS232, E.P.O Contact and USB Port Optional: SNMP, Modbus, Dry contact
Noise (DB)<50dB
Temperature (°F- °C)0°C - 40°C | 32°F - 104°F
Umidity<95%
Dimensions (W*D*H) in5.6*13.9*8.6 in | 5.6*15.6*8.6 in
Dimensions (W*D*H) cm14.2*35.3*21.6 cm | 14.2*39.6*21.6 cm
Weight (Lb - Kg)16.5 Lb - 7.5 Kg | 36.3 Lb - 16.5 Kg | 45.2 Lb - 20.5 Kg

Certifications

StandardsCE (lEC EN 62040-1; EMC IEC EN 62040-2; lEC EN 62040-3); UL1778

Download documentation

FERRUS 1-3k 120V Catalog