Power Range: 30-1200 kVA

Modular UPS

| IST6

Uninterruptible power supplies modular IST6 (30-1200kVA) are AEC’s three-phase modular UPS, UPS with modules hot extractable, in powers starting from 30kVA up to 1200kVA. The UPS IST6 series adopts a completely modular technology, ensuring constant redundancy of the UPS.

Their modularity allows future expansion in power up to 2.4MW. Available in six sizes, up to 120kVA | 300kVA and 600kVA | 800 kVA – 1000 kVA – 1200 kVA | and with an efficiency of up to 97% and maximum safety, IST6 is designed for medium and large data centers. Configurable directly from the display, wide flexibility and high overload capacity. The self-cleaning function reduces the risk of dust accumulation on the cards. The system includes the free contact card for alarms.

3:3

Modular

three UPS levels

kW = kVA

97% Efficiency

Modular ups features:

  • IGBT rectification technology with ultra-low input harmonics;
  • Eliminates pollution from the electricity grid and protects both the load and the electricity grid;
  • Large capacity up to 320kVA for a single cabinet;
  • Small footprint of only 0.5 square meters;
  • High resistance to ensure module reliability and hot exchange;
  • Rotating module thanks to the suspension technology of the module that improves efficiency and reduces operating costs;
  • Host and battery have reliable, double-layer protection mechanisms;
  • It has a BSC output to solve the problem of unsynchronized power supply.

3 year warranty.
Ideal for data centers, servers and industrial automation processes.

Accessories

By purchasing an AEC IST6 UPS (30-1200 kVA), the Dry Contact Card is included in the price, which provides a series of normally open or normally closed potential-free contacts to signal various UPS functions.
It is also possible to purchase different accessories separately to implement the functionality of the UPS:
External bypass = allows maintenance or repair / replacement of the UPS without interrupting the powered user.
Temperature sensor = monitors the batteries by compensating the charging current based on the ambient temperature thanks to a probe that communicates with the logic of the continuity system.
SNMP card = allows AEC to remotely monitore, assiste, test and operate the UPS anywhere in the world.

Dry Contact Card UPS Scheda Dry Contact

SNMP network card SNMP card for UPS

External-Bypass

External maintenance bypass for UPS

Dry Contact Card UPS Scheda Dry Contact

SNMP network card SNMP card for UPS

External-Bypass

External maintenance bypass for UPS

INPUT

VOLTAGE (VAC)380/400/415
TENSION / VOLTAGE TOLERANCES (VAC)L:L 138~485
FREQUENCY INPUT (HZ)40-70
BYPASS TENSION / VOLTAGE (VAC)-15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR≥0.99
THDI<5% (Non-linear at full load)
PHASES3+N+PE
BATTERIES (VDC)120-600 kVA: ±192 (±180~ ±276 settable) 800-1200 kVA: ±240 (±180~ ±276 settable)
CHARGING CURRENT (A) N×10 Maximum (N: number of power modules)

CERTIFICATIONS

STANDARDS AND CERTIFICATIONSCE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

OTHERS SPECIFICATIONS

TEMPERATURE (°C)0~40
HUMIDITY0%~95%
COMMUNICATIONRS485, MODBUS, Free Contact Card (SNMP optional)
NOISE (DB)120-600 kVA: < 65 | <70 800-1200 kVA: <70
POWER MODULE (KVA)120-600 kVA: 30 | 50 800-1200 kVA: 100
WEIGHT POWER MODULE (KG)120-600 kVA: 32 | 33 800-1200 kVA: 33
DIMENSIONS (L×W×H) (MM)120-600 KVA: 600×860×2000 | 1200×860×2000 800-1200 kVA: 1400*1000*2000 | 1800*1000*2000
WEIGHT (KG)120-600 kVA: UPS (180 | 224 | 427) Bypass Module (17 | 25 | 27) Power Module (30/50kW | 27 | 33) 800-1200kVA: UPS (580 | 650 | 740) Bypass Module (60 | 80 | 80) Power Module 100kW (55)

OUTPUT

POWER (KVA)120-600 kVA: 120 | 200 | 300 | 600 800-1200 kVA: 800 | 1000 | 1200
POWER FACTOR1
PHASES3+N+PE
WAVEFORMSinusoidal
TENSION / VOLTAGE (VAC)L-L:380,400,415 ±1%
FREQUENCY (HZ)50/60± 0.2%
DIFFERENCE 3 PHASES≤2 degrees
THD≤1% (Linear loads at full load), ≤4% (Non-Linear loads at full load)
MAX. SYSTEM EFFICIENCY120-600 kVA: 97% 800-1200 kVA: over 97%
PARALLELN+1 redundant
OVERLOAD105-115% Overload for 60mins, 116%-130% Overload for 10mins, 131%-150% Overload for 1 min, more than 150% Load transfers on Bypass

Download documentation

Catalog