400V UPS | 3 Phase Modular

Power Range: 60-1200kVA

The 400V UPS modular (30-1200kVA) are AEC’s range of three-phase modular UPS, UPS with hot-swappable modules, in powers starting from 30kVA up to 1200kVA in single structure. The UPS series adopts a completely modular technology, guaranteeing constant redundancy of the continuity system.
Their modularity allows future expansion in power up to 4.8MW. They are available in four sizes, up to 120kVA | 200kVA – 300kVA | 400kVA – 600kVA- 800kVA | 1000kVA-1200kVA | with an efficiency of up to 97% and maximum safety.
The UPS is designed for medium and large data centers. UPS configurable directly from the display, with great flexibility and high overload capacity. The self-cleaning function reduces the risk
of dust accumulation on the cards. The system includes the free contact card for alarms.

Category:

High-Efficiency 400V Three-Phase UPS Systems

Discover the cutting-edge features of AEC’s 400V Three-Phase UPS Systems, designed to offer outstanding power protection and high efficiency. These systems are tailored for high-demand business environments, supporting power capacities ranging from 60kVA to 200kVA, making them perfect for companies seeking robust power management solutions.

Key Features of 400V UPS Systems

Modular Design and Expandable Power Capacity

Our 400V UPS systems come with both fixed and scalable power capacities to accommodate the varying needs of modern businesses:

  • Fixed Power Capacity: The 60kVA model delivers consistent power, ideal for businesses with steady power requirements.
  • Expandable Options: Start with an 80kVA capacity and scale up to 120kVA or begin at 160kVA and extend to 200kVA through a user-friendly display interface. This flexibility allows businesses to adapt to growing power needs without external alterations.

User-Friendly Management and Configuration

Easily manage and customize your UPS settings through an intuitive display interface. Adjust battery setup and load capacities to optimize performance and efficiency for your specific operational needs.

Advanced Technology and Efficiency

Battery Test UPS
Touch Screen UPS

State-of-the-Art Inverter Technology

Our UPS systems use advanced three-level IGBT inverter technology to achieve up to 97% efficiency. This high level of efficiency reduces operating costs by lowering energy consumption and minimizing heat output, leading to a more sustainable operation.

Reliability and Maintenance

Enhanced Longevity and Self-Cleaning Mechanism

Equipped with a unique self-cleaning mechanism, our UPS systems significantly decrease dust buildup on crucial components, thus lowering maintenance needs and prolonging system life. A robust overload capacity ensures the system handles unexpected power surges without affecting performance.

Comprehensive Alarm System

Maintain operational security with our integrated alarm system. This system includes a free contact card that alerts you to any operational issues, enabling prompt action to ensure continuous protection of your critical equipment.

Touch Screen UPS

Display 4.3″ Inches | 60-80-100-120kVA

Display Modular UPS

Display 7″ Inches | 160-200kVA

Ensure the continuity of your business operations with AEC’s 400V Three-Phase UPS Systems, your reliable solution for efficient and expandable power management.

bypass mode UPS

TECHNICAL SPECIFICATIONS
MODELS MOD-120K MOD-200K | MOD-300K MOD-600K
POWER MODULES MOD-30K-J MOD-50K-J
INPUT
VOLTAGE (VAC) 380/400/415
TENSION TOLERANCES (VAC) L:L 138~485
FREQUENCY INPUT (HZ) 40-70
BYPASS TENSION (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) ±192 (±180~ ±276 settable)
CHARGING CURRENT (A) N×10 Maximum (N: number of power modules)
OUTPUT
POWER (KVA) 120 200 | 300 600
POWER FACTOR 1
PHASES 3+N+PE
WAVEFORM Sinusoidal
TENSION (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2 degrees
THD ≤1% (Linear loads at full load), ≤4% (Non-Linear loads at full load)
MAX. SYSTEM EFFICIENCY 97%
PARALLEL N+1 redundant
OVERLOAD 105-115% Overload for 60mins, 116%-130% Overload for 10mins,
131%-150% Overload for 1 min, more than 150% Load transfers on Bypass
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free Contact Card (SNMP optional)
NOISE (DB) < 65 <70
POWER MODULE (KVA) 30 50
WEIGHT POWER MODULE (KG) 32 33
DIMENSIONS (L×W×H) (MM) 600×860×2000 1200×860×2000
WEIGHT (KG) UPS 180 224 427
Bypass Module 17 25 27
Power Module 30/50kW 27 33
CERTIFICATIONS
STANDARDS AND CERTIFICATIONS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

Download the 400V UPS datasheet | Modular

TECHNICAL SPECIFICATIONS
MODELS MOD-800K MOD-1000K MOD-1200K
POWER MODULES MOD-100K-J
INPUT
VOLTAGE (VAC) 380/400/415
VOLTAGE TOLERANCES (VAC) L:L 138~485
FREQUENCY INPUT (HZ) 40-70
BYPASS VOLTAGE (VAC) -15% (-20%/-30% optional) ~+15%(+10% /+20% optional)
POWER FACTOR ≥0.99
THDI <5% (Non-linear at full load)
PHASES 3+N+PE
BATTERIES (VDC) ±240 (±180~ ±276 settable)
CHARGING CURRENT (A) N×10 Maximum (N: number of power modules)
OUTPUT
POWER (KVA) 800 1000 1200
POWER FACTOR 1
PHASES 3+N+PE
WAVEFORM Sinusoidal
VOLTAGE (VAC) L-L:380,400,415 ±1%
FREQUENCY (HZ) 50/60± 0.2%
DIFFERENCE 3 PHASES ≤2 degrees
THD ≤1% (linear loads at full load), ≤4% (non-linear loads at full load)
MAX. SYSTEM EFFICIENCY over 97%
PARALLEL N+1 redundant
OVERLOAD 105-115% Overload for 60mins, 116%-130% Overload for 10mins,
131%-150% Overload for 1 min, more than 150% Load tranfers on Bypass
OTHER SPECIFICATIONS
TEMPERATURE (°C) 0~40
HUMIDITY 0%~95%
COMMUNICATION RS485, MODBUS, Free contact card (SNMP optional)
NOISE (DB) <70
POWER MODULE (KVA) 100
POWER MODULE WEIGHT (KG) 33
DIMENSIONS (L×W×H) (MM) 1400*1000*2000 1800*1000*2000
WEIGHT (KG) UPS 580 650 740
Bypass Module 60 80 80
Power Module 100kW 55
CERTIFICATIONS
STANDARDS CE (Reference standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; Classification IEC EN 62040-3)

Download the 400V UPS datasheet | 3 Phase

Catalog UPS Power Supply 400V Modular

AEC Usa

Founded way back in 1968, the AEC Group, Allis Electric Co. Ltd, is a public company listed on the Taipei Stock Exchange since 1994.

The AEC group has specialized for more than 50 years in the production of UPS for the protection of the power supply of industrial plants.

CONTACTS

244 Biscanye Blvd Miami 33132 Florida USA

+1 7869919578

Copyright © 2022 | All Rights Reserved | Aec International Srl